Abstract
Failure modes for inter-level dielectric layers under accelerated test conditions have been evaluated for a range of dielectric diffusion barriers in copper/low-k structures. The dominant failure mechanism for both constant voltage tests and ramped voltage tests was mechanical cracking at the dielectric barrier/low-k interface. Few occurrences of copper diffusion through the bulk ILD were observed. A simple model for the dominant failure mechanism is proposed which hypothesizes crack formation due to the electrostatic force between interdigitated lines followed by copper extrusion into the cracks. The proposed model is consistent with measurements of interfacial adhesion strengths in Cu/low-k stacks.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Device and Materials Reliability
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.