Abstract

In this research, interlaminar shear strength of medium-density fiberboard (MDF) as obtained by a three-point short-beam shear test was examined. The three-point short-beam shear tests were conducted on MDF, which were used in a previous research on the asymmetric four-point bending tests. Interlaminar shear strength was measured using the specimens with rectangular and I-shaped cross sections with varying the span lengths. It is less useful to obtain the interlaminar shear strength by the three-point short-beam shear test than the asymmetric four-point bending test because the effective span length for obtaining an appropriate value of interlaminar shear strength is extremely restricted.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.