Abstract

The usefulness of the end-notched flexure (ENF) test for measuring G(IIc) for toughened composites was evaluated. Calculations were made using the measured flexural compliance from the ENF test and the measured axial modulus. Tests were conducted on three different composite materials, using laminates with two different span lengths and insert sizes. The error associated with neglecting nonlinear terms in the displacement-curvature relationship was analyzed to demonstrate the influence of specimen geometry on G(IIc) measurement. It is concluded that G(IIc) measurement may vary with the method of calculation, span length, or insert thickness, but these effects are minor compared to the large differences in measurements obtained for different materials. Hence, the ENF test is a valid one for screening materials for improvements in interlaminar shear fracture toughness.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.