Abstract
This paper deals with the open-phase fault and the winding inter-turn short circuit fault modelling of 3-phase interior (salient pole) permanent magnet synchronous motor (IPMSM). We found out that these are the most frequent non-mechanical failures in IPMSM drives. This paper is focused on mathematical model and Matlab/Simulink model of such drive. The stationary reference frame is used for representation of a model, according to the stator winding asymmetry (caused by fault in one phase winding). Model with faults is built on SimScape Matlab/Simulink toolbox. The results indicate that this is powerful way how to simulate complex electromechanical system in non-standard operational regime. It suggests that this model can be used for verifying the fault detection algorithms based on the stator current signature analysis or the state observers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.