Abstract

Abstract Stress corrosion cracking (SCC) of type 304 (UNS S30400) stainless steel (SS) was studied using fracture mechanics-type standard compact tension (CT) specimens in simulated boiling-water reactor (BWR) environments at 288°C. Tests were performed under constant loading. Crack lengths and crack growth rates (CGR) were determined by the reverse direct current (DC) potential drop method. Fractography was used to determine the mode of cracking and to confirm validity of the potential drop method for crack length determination. Test environments were high-purity deionized water with < 10 ppb to 440 ppb dissolved oxygen (O2) 0 ppb to 570 ppb hydrogen peroxide (H2O2), and 14 ppb to 150 ppb dissolved hydrogen (H2). CGR were found to be 4.9 × 10−8 mm/s to 3.0 × 10−7 mm/s at an initial stress intensity (K) of 31 MPa√m (100 kgf/mm1.5) in simulated normal water chemistry (NWC). However, the CGR was < 1 × 10−9 mm/s in simulated hydrogen water chemistry (HWC). CGR decreased with decreasing corrosion potential (E...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.