Abstract
The study is on the variation of pressure in different faces of rectangular plan-shaped tall buildings with interference conditions due to the presence of another building with the same shape and dimension connected through a multipurpose bridge. The analysis is done on computational fluid dynamics (namely ANSYS CFX) for 0° to 90° wind incidence angle (WIA). The buildings are spaced 60 m from each other. Different cases have been taken and analyzed based on the different positions of the bridge (i.e., 0.33H, 0.5H, and 0.67H) and compared with the isolated case (i.e., buildings without the bridge). A comparison study has been done in the form of interference factor (IF), so we can clearly understand the effect of the bridge at different heights of the building and isolated conditions on rectangular plan-shaped buildings. The study shows that when the bridge is at 0.5H and 0.33H, the force coefficient along X and Y produces similar results to an isolated condition for WIA of 60° and 30°, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.