Abstract

Local peak pressure coefficients between two buildings were studied by using wind tunnel experiments for various locations, different height ratios of interfering building and wind directions. The measured local peak pressure coefficients were compared to those obtained previously from a study on an isolated building. This study also investigated interference effects for local peak pressures on a principal building with various configurations and different height ratios of an interfering building. The experimental results have been examined and presented from the viewpoint of cladding design. The results show that highest peak suctions on a principal building increased with increase in height ratios of the interfering building. The oblique configuration generated more severe peak suction than the tandem configuration. To examine the interference effects for local peak pressures in detail, interference factors for maximum positive and minimum negative peak pressures at each measurement point ( i, j) of the principal building for all wind directions are presented and discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.