Abstract

Liquid holdup and interfacial areas were measured in packed columns with cocurrent downward flow. An empirical equation of liquid holdup Φt is presented in terms of Reynolds numbers of gas Reg(=dsGg/μg) and liquid Rel, surface shape factor of packing φ, void fraction e and ratio of packing to column diameter dp/T, where the ratio is smaller than 0.13. This equation is different for the dispersed bubble flow and other flow regions. The empirical equation of interfacial area ap in the respective flow regions varies as follows: apdp/(1-Φl/e)=ωΦ-mRenlReqg(dp/T)-twhere ω=7.5×10-5, m=Q.2, n=Q.15, q=2/3, t=2.5 for spray flow; ω=2.2×10-4, m=0.3, n=2/3, q=0.2, t=2.5 for pulse flow; ω=3.9×10-3, m=0.1, n=0.4, q=p. t=2 for trickle flow; ω=2.8×10-7, m=0.9, n=1.8, q=0, t=3.3 for dispersed bubble flow. The equation of the boundary in the respective flow regions was found by equating the two of them. The predicted boundaries are in excellent agreement with the literature data given from the analysis of liquid pulse frequencies. The predictions for interfacial areas also agree well with the literature data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.