Abstract

A capture cross section value is often assigned to Si–SiO2 interface defects. Using a kinetic variation of the charge pumping technique and transition state theory, we show that the value of capture cross section is extremely sensitive to the measurement approach and does not provide any meaningful insight into the physics involved. We argue that capture cross section is neither a physical property of interface defects nor is there any need to assign capture cross section values.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.