Abstract
A focused ion beam (FIB) was used to characterize deformation and bonding behavior of titanium particles, cold sprayed onto a titanium surface. By milling away half of each particle a cross-section was obtained, revealing the particle–substrate interface. It was found that in some sections, voids lined the interface due to mismatch in particle- and substrate-surface topologies. In other places, the interface could not be discerned due to closure of the voids. It is shown that this effect was related to adiabatic shear instability, which caused violent jetting, ejection of molten material from the particle, and thermal softening of the interfacial layers. Deformation characteristics and variation in splat profiles due to microstructural influences, and the effect of particle size are also discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.