Abstract
This article is addressed to the inductivity of the feeder transformer influence on of the plate-type ozone generator operating modes. The equation characterises the ozone generator interconnected operation with the transformer, in discharge and non-discharge modes is represented. Use of the near-resonant mode of operation is proposed with a view to reach maximum output capacity. With that end in view, it is proposed to use the transformer with higher inductance. Oscillograph charts of two modes of operation of the ozone generator are analysed. Current waveform factors are determined by the harmonic analysis method. Experiments proved that current waveform factor increase in value for the account of continuous discharge is conductive to increase of ozone output by 25-30 % and power loss reduction by 10-15 %.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.