Abstract

Measurements made during cycle 1 operation of Commonwealth Edison Company's Zion Unit 2 pressurized water reactor core were used to validate the Electric Power Research Institute Advanced Recycle Methodology Program. In addition to the usual reaction rate and axial trace measurements for determining power distributions, gamma scan measurements were available to provide additional data to validate the calculated power shapes. The parallel occurrence of gamma scan measurements and standard nuclear instrumentation measurements provided a unique opportunity to intercompare the results of these measurement methods. The calculated X-Y gamma scan behavior supported the behavior of the calculated X-Y reaction rates. The measured X-Y gamma scans were found to be more accurate than the measured X-Y reaction rates, with the latter showing significant differences among some symmetrically located assemblies. For both types of measurement, however, the modeling of the asymmetrically loaded assembly located furthest in the core periphery produced the poorest results. The axial gamma scan calculation proved very accurate except at the inlet and outlet regions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.