Abstract

Limb infrared spectra calculated by the Optimized and Precise Radiative Transfer Algorithm (KOPRA), GENLN2, Reference Forward Model (RFM), and Simulation Program for Infrared Radiative Transfer (SPIRT) radiative transfer algorithms were intercompared for both local thermodynamic equilibrium (LTE) and non‐local thermodynamic equilibrium (non‐LTE) conditions, in the latter case for given profiles of vibrational temperatures. The overall agreement is usually better than approximately 0.5%, except for isolated phenomena that have been assessed in more detail. Most spectral radiance discrepancies occur also under LTE conditions and are attributed to different treatment of far wings of lines, integration schemes, and mass‐weighted averaging of atmospheric temperature and pressure along slant path segments as well as different spectral sampling during the calculation of monochromatic radiances.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.