Void fraction simulating stratified air–water flow in cylindrical tubes of different radii was measured using transmission and scattering of gamma rays. A simple experimental set-up using 137Cs γ-ray point source of 10μCi and NaI(Tl) detector was used. The void fractions determined from Compton–Compton scattering and transmission peaks were found in good agreement with the real void fractions. However, deviations were noticed between the results obtained from traditional Compton scattered gamma rays and real void fraction. It was shown that sensitivity of gamma ray scattering is better than the transmission measurements. The set-up used in the present work is simpler than those existing in literature and radiation safety and shielding requirements are minimized.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.