Abstract

Intercomparison measurements have been made on Perspex (polymethylmethacrylate) and stainless steel A310 by pulse transient and stepwise transient methods. Both methods belong to the transient techniques that give specific heat, thermal diffusivity, and thermal conductivity within a single measurement. Measuring times and time windows for data evaluation are given for both measuring techniques. Criteria for characteristic parameters of the ideal model by pulse transient are given. Experimental results are compared with recommended and published data for thermal conductivity, specific heat, and thermal diffusivity. Deviations from published and recommended data were found. Data uncertainties in thermal conductivity caused by these deviations are up to 6% for Perspex and up to 10% for stainless steel A310.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.