Abstract

Concern about limited surface durability has been the main reasons for recommendations by advisory committees and government health authorities, not to reu-use sulphur-treated soda-lime glass (type II) bottles for intravenous solutions. In order to contribute specific data, the interactions of slightly acid and neutral parenteral solutions with ammonium sulphate-treated type II glass bottles have been investigated. It was established that the amounts of silica, sodium and calcium released into the solution are not greater than the potential background contamination from the raw materials. The number of particles in the solution was well below the limits set by the British Pharmacopoieia and not much higher than the lowest background count practically achievable. On an average, bottle surfaces released less material after the first time of use. Bottle-to-bottle variations revealed by scanning electron microscopy point at problems in achieving smooth, evenly surface-treated bottle surfaces during bottle manufacture.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.