The shear performance of precast segmental bridge column (PSBC) epoxy-free dry joints was investigated. Ten PSBC dry joint specimens were tested under monotonic direct shear loading. The design parameters include sectional shape, with or without shear keys, key number and geometry, and confining stress. The shear resistance-relative vertical displacement curves were recorded. The damage patterns and failure mechanism of tested specimens were analyzed. Shear strength formulas for prismatic, castellated, and flat dry joint were derived through data regression. The applicability of proposed formulas together with those from literature was investigated. Finally a finite element (FE) model was calibrated to study the friction contribution to shear capacity at various confining stresses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.