Abstract
To present the variations in the target delineation and the planning results of intensity-modulated radiation therapy (IMRT) for breast cancers. We requested the target volumes and organs at risk delineation for two cases of left breast cancers, and evaluated the IMRT plans including the supraclavicular and internal mammary node irradiation. Twenty-one institutions participated in this study. Differences in the planning target volume among institutions reached up to three-times for breast-conserving surgery (BCS) case and five-times for mastectomy case. Mean heart doses ranged from 3.3 to 24.1 Gy for BCS case and from 5.0 to 26.5 Gy for mastectomy case. Ipsilateral lung volumes receiving more than 20 Gy ranged from 4.7 to 57.4% for BCS case and from 16.4 to 55.5% for mastectomy case. There were large variations in the target delineation and planning results of IMRT for breast cancers among institutions. Considering the increased use of breast IMRT, more standardized protocols are needed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.