Abstract

The purpose of this study was to test whether a handheld magnifier could be used as an accurate instrument to examine the periapical radiographs and measure the marginal bone levels around dental implants system. A radiologic evaluation of marginal bone loss around 11 Astra Tech (Astra Tech AB, Mölndal, Sweden) oral implants was performed. A total of 22-recorded readings of mesial and distal bone loss were performed using a handheld magnifier with a graticule. There were 3 independent examiners who determined radiographic bone assessment. Thevalues of interclass correlation coefficient for the agreement between pairs of examiners showed a relatively high agreement (0.993 for A vs B, 0.995 for B vs C, and 0.995 for A vs C) and the same for intra-examiner reliability result (0.998 for B vs B). These results showed that a handheld magnifier could be used as a simple, reliable, and reproducible method for measuring bone loss around oral implants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.