Abstract

The purpose of this study was to examine the intra- and interrater reliability of measuring shoulder range of motion (ROM) and strength among patients diagnosed with subacromial impingement syndrome (SAIS). Twenty-five patients (14 female patients; mean age, 60.4± 7.84 years) diagnosed with SAIS were assessed to determine the intrarater reliability for glenohumeral ROM. Twenty-five patients (16 female patients; mean age, 60.4± 7.80 years) and 76 asymptomatic volunteers (52 female volunteers; mean age, 29.4± 14.1 years) were assessed for interrater reliability. Dependent variables were active shoulder ROM and isometric strength. Intrarater reliability was fair-to-excellent for the SAIS patients (intraclass correlation coefficient [ICC], 0.52–0.97; standard error of measurement [SEM], 4.4°–9.9° N; coefficient of variation [CV], 7.1%–44.9%). Based on the ICC, 11 of 12 parameters (92%) displayed an excellent reliability (ICC> 0.75). The interrater reliability showed fair-to-excellent results (SAIS patients: ICC, 0.13–0.98; SEM, 2.3°–8.8°; CV, 3.6%–37.0%; controls: ICC, 0.11–0.96; SEM, 3.0°–35.4°; CV, 5.6%–26.4%). In accordance with the intrarater reliability, glenohumeral adduction ROM was the only parameter with an ICC below 0.75 for both samples. Painful shoulder ROM in the SAIS patients showed no influence on the quality of reliability for measurement. Therefore, these protocols should be considered reliable assessment techniques in the prevention, diagnosis, and treatment of painful shoulder conditions such as SAIS.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call