Abstract

To compare treatment plans for multileaf collimators (MLCs) with different leaf widths and different finite pencil beam (FPB) sizes, to determine the planning quality and delivery efficiency of segmented MLC (SMLC) delivery of intensity-modulated radiation therapy (IMRT) for malignant pleural mesothelioma (MPM). Computerized tomography images of 10 right-side MPM patients were used for this planning study on a CORVUS treatment-planning system (NOMOS Corporation, Sewickley, PA) for a Varian Millennium 120-MLC (Varian Medical Systems, Palo Alto, CA). Three beam models were used. The first model forced two 0.5-cm MLC leaves to move in tandem to simulate a 1-cm leaf-width MLC and a FPB size of 1 x 1 cm2. The second model used 0.5-cm leaves with a FPB size of 0.5 x 1 cm2 (1 cm in the direction of leaf movement). The third model used 0.5-cm leaves, with a FPB size of 0.5 x 0.5 cm2. For optimization, the same dose constraints and beam parameters were used for each data set. Tissue heterogeneity corrections were used during optimization and dose calculation. Plans were optimized such that the clinical target volume received 50 Gy in 25 fractions. Dose distributions to the target and normal structures were evaluated. The number of monitor units, the number of segments, and delivery times were used to evaluate delivery efficiency. All three beam models could be used for IMRT planning for MPM. The doses to clinical target volume, spinal cord, lung, liver, heart, and contralateral kidney were acceptable with all three beam models. The 0.5 x 0.5-cm2 beam model used the most monitor units (6883 +/- 974 vs. 3332 +/- 406 and 3407 +/- 443 for the 1 x 1-cm2 and 0.5 x 1-cm2 models, respectively) and treated the most segments (4297 +/- 802 vs. 1357 +/- 156 and 1767 +/- 212 for the 1 x 1-cm2 and 0.5 x 1-cm2 models, respectively). The plan generated with the 1 x 1-cm2 model required the least amount of time to deliver. The quality of the MPM IMRT plans generated with the three beam models presented here was similar; however, the 1 x 1-cm2 model provided the most efficient delivery of MPM IMRT with the CORVUS planning system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.