Abstract

A forced convective mass transfer coefficient was electrochemically measured for a cylindrical bundle of transverse needle-fins ϕ1 × 10.9, applied as the rotor porous matrix of a rotary heat regenerator. The baffle inside the rotor was present. The technique based on the ferricyanide–ferrocyanide redox reaction controlled at the cathode, in the presence of a sodium hydroxide based electrolyte, was used in this experiment. A set of the six neighbouring fins, connected in parallel, was the cathode. The distribution of the mass transfer coefficient according to different static rotor angle position and the mean mass transfer Chilton–Colburn coefficient correlation j M = j M (Re) for rotation numbers, Ro: 0, 0.8, 1.6 and 2.0 were stated in the mean Reynolds number, Re, range 180–985. The comparison was made between the convective heat fluxes of the pin-fins and the sheet rotor, for Ro = 0.

Full Text
Published version (Free)