A novel approach for the intensification of ozonation of water and wastewater is presented using a highly efficient and compact multi-orifice oscillatory baffled column (MOBC) ozonation contactor. The MOBC uniquely yielded full (i.e. 100%) use of the ozone supplied with a very short (2.25min) liquid contact time under continuous operation and reducing the need of further gas–liquid contacting equipment downstream from the MOBC. The increased performance of the MOBC ozonation reactor was benchmarked against a bubble column (BC) design and resulted in 20% increase on the rate of p-hydroxybenzoic acid (p-HBA) degradation, 75% increase in the rate of mineralisation of p-HBA per mole of ozone consumed, and 4.5–5.0-fold increase in the rate of mineralisation of p-HBA per mole of ozone supplied. This results from the very small size of bubbles (few hundreds of microns) and enhanced gas–liquid mass transfer and hold-up generated in the presence of small fluid pulsations and orifice baffles.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.