Abstract

The concentration of ultrafine airborne particles is continuously increasing, and research has shown that it has adverse effects when inhaled into the human body. Accordingly, there is a growing demand for a measurement network utilizing sensors to evaluate an individual's exposure to these airborne particles. However, the current low-cost sensors have the limitation of low accuracy. To solve this, we devised a method to calibrate a low-cost mass concentration sensor accurately in real time. In a previous study, we developed an analyzer that could measure the effective density and nanoparticles that cause the low accuracy of the mass concentration sensor. However, it had a hardware stability problem when used to monitor the outside air for a long period. This has been improved by modifying the shape of the Micro-electromechanical system (MEMS)-based chip integrated with the electrical/inertial analysis technology. Hence, the device can now operate with sufficient stability in the outdoor air. In addition, the retrieval algorithm used to convert the measured current values into the effective density and nanoparticle size distribution was prone to errors. It was modified to a deep learning-based physical parameter conversion algorithm to minimize the errors. Thus, we developed a standalone analyzer that integrates the improved nanoparticle and effective density analyzer, temperature and humidity sensor, and low-cost mass concentration sensor. In addition, we developed a technique to calibrate the mass concentration sensor data accurately in real time based on the data measured by each sensor and analyzer and a deep learning-based mass concentration calibration algorithm. The calibration precision was confirmed through comparative evaluation of the analyzer with the results of a beta attenuation mass monitor. In the future, this analyzer can be utilized to build a sensor network that precisely monitors the mass concentration in a large area through multi-point deployment. Alternatively, it can be used for monitoring the mass concentration in an indoor private space, where it is difficult to place expensive and large equipment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.