Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background We have previously developed the sense protocol functional substrate mapping technique for VT ablation(1). However, functional substrate characterizaiton can involve protracted mapping time. Purpose We incorporated the integration of MRI data using ADAS-3D software into the mapping workflow, to integrate structural mapping information into the functional mapping substrate characterization, in order to improve procedural efficiency. Methods CMRs were performed in 20 patients with ischemic related VT and VT therapy in the previous 6 months. These were processed with the ADAS-3D software to characterize the extent of ventricular scars and also ADAS corridors which may correlate with VT channels. Focused substrate maps were then performed in patients, guided by the extent of ADAS scar and corridors, looking at the scar substrate in intrinsic rhythm and then functional channels using single extra pacing from the RV at 20ms above ERP (SENSE2 Protocol). Specifically healthy areas 2cm beyond the scar borderzone based on ADAS were not mapped, in order to reduce substrate mapping time and complete geometries were not created. Following delineation of functional channels pacemapping and entrainment mapping were used to confirm targets for ablation. The ADAS 3D MRI was integrated into the into the VT substrate map on Ensite-Precision with alignment to the aorta, RV and PA (Figure 1). We compared our data with previous functional mapping data without the integration of MRI. Results 20 patients (age 70 years; 19 male subjects) underwent ablation. Mean EF 28%. Median procedure time was 161 minutes compared with 246 minutes (in our previous study)(p=<0.001) Mean substrate mapping time was 32 mins vs 63 mins (p=<0.001). Mean ablation time was 22 mins vs 32 mins (p=0.11). 85% (17 of 20) patients were free from symptomatic VT/ anti-tachycardia pacing or implantable cardioverter defibrillator shocks at a median follow-up of 171 days. The mean VT burden was reduced from 22 events per patient in the 6 months’ pre-ablation to 1 event per patient in the median follow up period of 171 days post ablation (p=0.02). Mean shocks per-patient burden decreased from 3.5 to 0.08 in the same time period(p=0.03). Conclusion The SENSE2 protocol involves the integration of structural and functional data into the VT workflow for substrate characterization. It enables focused substrate maps to be performed without the need for complete geometry to be created in large ventricles. Outcomes compare favourably with our previous data but with significantly shorter procedure times. This streamlined workflow has the potential to improve care in VT ablation by shortening procedure times with similar outcomes which may reduce risks for the patient. Figure 1: Comparison of Voltage Map with MRI scar & corridors using ADAS

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.