Abstract

The aim of this project is to study the capability of cool roof system in the reduction of heat transmission through metal roof into an attic. The cool roof system is designed in active and passive methods to reduce the thermal loads imposed to a building. Two main features are introduced to this cool roof system, which is thermal insulation coating (TIC) and moving air cavity (MAC) that served as active and passive manner, respectively. For MAC, two designs are introduced. Normal MAC is fabricated by six aluminium tubes whereby each aluminium tube is made up by sticking up of five aluminium cans. While improved MAC is also made by six aluminium tubes whereby each aluminium tube is custom made from steel rods and aluminium foils. MAC provides ventilation and heat reflection under the metal roof before the heat transfer into attic. It also coupled with three solar powered fans to increase heat flow inside the channel. The cool roof that incorporated TIC, MAC with solar powered fans and opened attic inlet showed a significant improvement with a reduction of up to 14 °C in the attic temperature compared to conventional roof system.