Abstract
Background and objectiveWearable inertial devices integrated with modelling and cloud computing have been widely adopted in the sports sector, however, their use in the health and medical field has yet to be fully realised. To date, there have been no reported studies concerning the use of wearables as a surrogate tool to monitor knee joint loading during recovery following a total knee joint replacement. The objective of this study is to firstly evaluate if peak tibial acceleration from wearables during gait is a good surrogate metric for computer modelling predicted functional knee loading; and secondly evaluate if traditional clinical patient related outcomes measures are consistent with wearable predictions. MethodsFollowing ethical approval, four healthy participants were used to establish the relationship between computer modelling predicted knee joint loading and wearable measured tibial acceleration. Following this, ten patients who had total knee joint replacements were then followed during their 6-week rehabilitation. Gait analysis, wearable acceleration, computer models of knee joint loading, and patient related outcomes measures including the Oxford knee score and range of motion were recorded. ResultsA linear correlation (R2 of 0.7–0.97) was observed between peak tibial acceleration (from wearables) and musculoskeletal model predicted knee joint loading during gait in healthy participants first. Whilst patient related outcome measures (Oxford knee score and patient range of motion) were observed to improve consistently during rehabilitation, this was not consistent with all patient's tibial acceleration. Only those patients that exhibited increasing peak tibial acceleration over 6-weeks rehabilitation were positively correlated with the Oxford knee score (R2 of 0.51 to 0.97). Wearable predicted tibial acceleration revealed three patients with a consistent knee loading, five patients with improving knee loading, and two patients with declining knee loading during recovery. Hence, 20% of patients did not present with satisfactory joint loading following total knee joint replacement and this was not detected with current patient related outcome measures. ConclusionsThe use of inertial measurement units or wearables in this study provided additional insight into patients who were not exhibiting functional improvements in joint loading, and offers clinicians an ‘off-site’ early warning metric to identify potential complications during recovery and provide the opportunity for early intervention. This study has important implications for improving patient outcomes, equity, and for those who live in rural regions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.