Abstract

The off grid electrification by utilizing Integrated Renewable Energy System (IRES) is proposed to satisfy the electrical and cooking needs of the seven-uneletrified villages in the Almora district of Uttarakhand state, India. Four different scenarios are considered during modeling and optimization of IRES to ensure reliability parameters such as energy index ratio (EIR) and expected energy not supplied (EENS). The optimum system reliability, total system cost and cost of energy (COE) have also been worked out by introducing the customer interruption cost (CIC). The four different renewable energy scenarios have been compared for the considered study area using the LINGO software version 10. The fourth renewable energy scenario accounting 44.99% micro hydropower (MHP), 30.07% biomass, 5.19% biogas and 4.16% solar energy along with the additional resources of wind (1.27%) and energy plantation (12.33%) has been found to be the best among the different options considered. Furthermore, the optimal reliability for the fourth IRES system has been found to be 0.95 EIR at the optimized cost of Rs 19.44 lacs with estimated COE of Rs 3.36 per kWh. The COE obtained using LINGO software and HOMER software has also been compared and briefly discussed for all the four scenarios. In order to verify feasibility and cost of system for different biomass fuel prices, a sensitivity analysis has also been carried out and it has been found that the fourth scenario is more sustainable than the other considered options.