Abstract

The new C-2W experiment (also called Norman) at TAE Technologies, Inc. studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes over 700 magnetic sensors, four interferometer systems, multi-chord far-infrared polarimetry, two Thomson scattering systems, ten types of spectroscopic measurements, multiple fast imaging cameras with selectable atomic line filters, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. Most of these diagnostic systems are newly built using experience and data from the preceding C-2U experiment to guide the design process. A variety of commercial and custom acquisition electronics collect over 4000 raw signals from the C-2W diagnostics. These data are processed into physics results using a large-scale database of diagnostics metadata and analysis software, both built using open-source software tools.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.