Abstract

The compatibility of two operational constraints—operation above the L–H power threshold and at low power to divertor—is examined for ITER long pulse H-mode and hybrid scenarios in integrated core–scrape off layer (SOL)–divertor modelling including impurities (intrinsic Be, He, W and seeded Ne). The core thermal, particle and momentum transport is simulated with the GLF23 transport model tested in the self-consistent simulations of temperatures, density and toroidal rotation velocity in JET hybrid discharges and extrapolated to ITER. The beneficial effect of toroidal rotation velocity on fusion gain is shown. The sensitivity studies with respect to operational (separatrix and pedestal density, Ne gas puff) and unknown physics (W convective velocity and perpendicular diffusion in SOL as well as W prompt re-deposition) parameters are performed to determine their influence on the operational window and fusion gain.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.