Abstract

The poor quality of potable water sourced from boreholes and hand dug wells at Yetunde Brown, Gbagada, Lagos informed the integration of geophysical, physicochemical and Water Quality Index (WQI) to assess the condition of groundwater in the study area. Twenty-Five (25) Vertical Electrical Sounding (VES) data were acquired and complemented with water samples collected from three boreholes and two hand-dug wells within the neighborhood of the study area. The VES data were partially curve matched and inverted. Physicochemical parameters were measured in water samples. The results of the VES data revealed four to five geo-electric layers which correspond to the topsoil (with layer thickness and resistivity values from 0.6 to 1.3 m and 20.1 to 361.4 Ωm respectively), clay (with layer thickness and resistivity of 1.7 to 5.2 m and 2.8 to 22.1 Ωm), sandy clay (with layer thickness and resistivity values of 2.8 to 5.9 m and 12.4 to 56.8 Ωm) and clayey sand (with layer thickness and resistivity values of 23.8 to 31.8 m and 7.2 to 94.2 Ωm). The sand in VES 7, 9, 12-18 and 20 has resistivity values ranging from 151 to 331.5 Ωm. The depth to the identified aquifers fluctuates between 23.8 and 90.4 m. The measured iron, chloride and lead ions are above World Health Organization (WHO) recommendation for potable water in some water samples. WQI calculated reflected poor quality for two boreholes only, which could be due to the unconfined aquifers delineated in the second and fourth geo-electric layers making the water vulnerable to contamination. The study recommended that bore hole should be sunk at VES 7, 9, 12, 13, 18 and 20 at depth between 31.8 to 66.6 m for exploitation of good quality water. Keywords: Groundwater, Electrical resistivity, Water quality index, physicochemical analysis, Aquifer

Highlights

  • Sorensen et al, 2005; Oyedele et al, 2007; Adeoti and Ishola 2008; Atakpo 2009; Adeoti et al, 2015; Adeoti et al, 2016)

  • This informed the use of electrical resistivity technique, physicochemical analysis and water quality index (WQI) to delineate the aquifer unit(s) and to assess the vulnerability of the groundwater to contamination in the study area

  • The fifth stratum in Vertical Electrical Sounding (VES) (1, 2, 3 and 5) is diagnostic of clayey sand/sand with resistivity values ranging from 26.5 to 60.2 Ωm but their layer thickness could not be determined because the current terminated within this horizon while the clayey sand /sand is replaced with clay/peat in VES 4 with resistivity value of 8.9 Ωm but the layer thickness could not be determined because the current terminated within this zone

Read more

Summary

Introduction

2005; Oyedele et al, 2007; Adeoti and Ishola 2008; Atakpo 2009; Adeoti et al, 2015; Adeoti et al, 2016). Water quality index (WQI) is essential because it is one of the most effective tools for the assessment and management of surface and groundwater. Yetunde Brown Estate is a structured residential community that has been faced with the problem of poor water quality and the problem is taking toll on the health status of the residents. This informed the use of electrical resistivity technique, physicochemical analysis and water quality index (WQI) to delineate the aquifer unit(s) and to assess the vulnerability of the groundwater to contamination in the study area

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.