Abstract

This paper presents an indoor localization system based on a frequency modulated continuous wave radar in the industrial-scientific-medical band at 5.8 GHz. An integrated active pulsed reflector behaves as a backscatter by regenerating the incoming phase with phase coherent startup at a constant frequency. The base station (BS) determines the distance to this reflector with a round-trip time-of-flight measurement. The active pulsed reflector is built around a switchable and tunable oscillator. The circuit has been fully integrated in a 0.18-¿m CMOS technology. Outdoor measurements revealed a positioning accuracy of 15 cm, while in a harsh multipath environment with omnidirectional antennas a positioning accuracy of 32.88 cm was measured. The localization system is capable of detecting multiple reflectors at the same time, and no synchronization between BSs is needed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.