A simple filter paper technique is described for demonstrating and measuring insulin loss at the injection site in children with type 1 diabetes mellitus. Using this technique in a cohort of 19 children during a 7-day period, measurable fluid was demonstrated at the injection site in 68% of children at least once and was present following 23% of all injections. In nearly 80% of cases the insulin loss probably represented less than 1 unit but could on occasions be 2 units or more or up to 18% of the injected dose. Insulin losses were observed following injections given by children themselves and by parents. There was no significant relationship between insulin dose and insulin loss. Insulin losses at the injection site are frequent and, although usually small in amount, are a potential source of blood glucose variability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.