Abstract

We have been studying quench-induced 'dynamic' breakdown characteristics of LHe and have already found that the electrical insulation performance of LHe was degraded drastically by the thermal bubble disturbance due to quench of superconductors. In this paper, in order to improve the insulation performance of LHe under quench conditions, we measured dynamic breakdown and prebreakdown characteristics of pressurized LHe. Experimental results revealed that breakdown voltage of LHe under quench conditions at 0.2 MPa was greatly improved, reaching 2 to 4/spl times/ compared with that at atmospheric pressure under both uniform and non-uniform electric fields. Moreover, for practical and efficient insulation design of superconducting power apparatus, we investigated the dynamic breakdown voltage of LHe as functions of pressure and gap length.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call