Abstract

A partial discharge (PD) occurring in the insulation of the stator winding of the generator is a symptom of the deterioration of the insulation system, PD is a very short duration current and/or voltage pulse, about 1-5 ns. Generally a PD emits a broad band electromagnetic wave (/spl sim/GHz). We developed a new system for detecting the microwave emitted from a PD. From the point of view of predicting an accident caused by the insulation breakdown of the generator winding, it is important to assess the condition of the winding. We applied our system to a dielectric breakdown test to know the relation between the characteristics of the microwave and the condition of the insulation system of the winding. The dielectric breakdown test is useful for estimating the minimum breakdown voltage which is a criterion of the insulation condition of the winding. Experimental results showed that this system was able to assess the insulation condition by measuring the number of the pulses of microwave frequency per voltage cycle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.