Abstract

BackgroundIn case of high sacral slope, anterior lumbosacral fusions can be performed by retroperitoneal or transperitoneal approach using a reversed Bohlman technique with an autologous corticocancellous fibular graft. The use of a trans-lumbosacral implant can avoid the iatrogenic effects but currently, there is no implant specifically designed for this fusion technique. Could the IFUSE implant from SI BONE replace a fibular graft to avoiding the iatrogenic effect induced by sampling during a Reverse Bohlman technique? Patients and MethodsWe present the case of a 38-year-old woman with L5S1 interbody pseudarthrosis after posterior fixation for grade 2 L5-S1 spondylolisthesis with isthmic lysis of L5, and that of a 69-year-old woman who underwent a posterior T4 fusion to the pelvis for degenerative scoliosis. Both required a trans-lumbosacral instrumented fusion via an anterior approach using the reverse Bohlman technique. Surgical technique was described. ResultsThere were no perioperative or postoperative complications. At 6 months, the patients reported a decrease in lumbar and radicular symptomatology. There were no infectious, neurological or vascular complications. CT-scans confirmed the good position and stability of the IFUSE implant. DiscussionWe present an innovative interbody grafting technique adapted to spines with high pelvic incidence. The surgical technique is safe, minimally invasive, and reduces surgical iatrogeny. The short and medium-term results are positive but require longer-term follow-up and a larger cohort.