Abstract

In the framework of a collaborative project between ASME, NASA, and NIST, instrumented Charpy tests have been performed at liquid nitrogen temperature (77 K, or 196 C) on specimens extracted from the center of four 316L welded stainless steel plates, each produced by a different vendor. Although the plates were produced in accordance with the same specifications from the same material (316L), clear differences in impact toughness have been observed, with the toughest welded plate exhibiting more than twice the absorbed energy of the least tough. Besides impact toughness, the availability of instrumented Charpy data has also allowed deriving estimates of dynamic yield strength and shear fracture appearance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.