Abstract

The radiometric calibration procedure, applied on VNREDSat-1 raw data shall correct and minimize the radiometric non-uniform gain and offset, occurred by the nature of the optical payload. The procedure is based on the radiometric model, built to transform the incoming radiance into camera output signal. Within this radiometric model, the radiometric parameters such as dark noise and pixel response non-uniformity shall be separated. The output signal of dark noise shall be measured by capturing image scene of the ocean at night. The output signal of pixel response non-uniformity shall be measured by capturing image scene of uniform radiance image scene such as the dessert or grass field. All the radiometric calibration parameter after calculated shall be saved into a calibration file, which is kept on the control station and image processing station.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.