Abstract
The CMS Electromagnetic Calorimeter consists of roughly 76000 lead tungstate (PbWO4) crystals and almost 25000 Printed Circuit Boards (PCBs) of 5 different types. About 5500 Gigabit Optical Links are used to process the signals from the photo-detectors and to send the resulting data to the off-detector electronics. The integration of the electronics is described together with its cooling system, mechanical supports, the low voltage distribution, various signal cables and optical fiber patch panels. Complexity and installation sequence require tests at each step of the installation. The test strategy during the installation is described and results of the system performance achieved are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.