Abstract
The time-dependent phase error induced by the instability of projection light source (IPLS) is systematically studied for phase-shifting profilometry (PSP). The IPLS of the projection device is investigated by a specially designed experimental setup. Based on the results of the investigation, a new mathematical model to analyze the time-dependent phase error induced by IPLS is established and verified. Two real-time phase error correction methods using a new designed three-dimensional shape measurement system are proposed for the effect of IPLS. Experimental results demonstrate the two methods can effectively eliminate the induced time-dependent phase error with a good robustness and high accuracy. The two real-time correction methods for PSP will be promising for high-accuracy measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.