Abstract

BackgroundElevated intraocular pressure (IOP) is a major risk factor for the development and/or progression of glaucoma, and a large diurnal IOP fluctuation has been identified as an independent risk factor of glaucoma progression. However, most previous studies have not considered the repeatability of 24-hour IOP measurements. The aim of this study was to evaluate the instability of 24-hour IOP fluctuations in healthy young subjects.MethodsTen healthy young volunteers participated in this prospective, cross-sectional study. Each subject underwent 24-hour IOP and systolic/diastolic blood pressure (SBP/DBP) assessments both in sitting and supine positions every 3 hours, once a week for 5 consecutive weeks. Mean ocular perfusion pressure (MOPP) was then calculated for both positions. The intraclass correlation coefficients (ICCs) of maximum, minimum, and fluctuation parameters were computed for IOP, SBP/DBP, and MOPP. Fluctuation was defined as the difference between maximum and minimum values during a day.ResultsAmong the serial measurements taken over a 24-hour rhythm, the maximum/minimum values of IOP, as well as BP, showed excellent agreement: regardless of position, all ICC values were over 0.800. Most of the BP fluctuation values also showed excellent agreement. IOP fluctuation, however, did not show excellent agreement; the ICC of sitting IOP fluctuation was just 0.212. MOPP fluctuation also showed poor agreement, especially in the sitting position (ICC, 0.003).ConclusionOn a day to day basis, 24-hour IOP fluctuations were not highly reproducible in healthy young volunteers. Our results imply that a single 24-hour IOP assessment may not be a sufficient or suitable way to characterize circadian IOP fluctuations for individual subjects.

Highlights

  • Elevated intraocular pressure (IOP) is a major risk factor for the development and/or progression of glaucoma, and a large diurnal IOP fluctuation has been identified as an independent risk factor of glaucoma progression

  • There was no a significant difference between the lOP readings obtained by Goldmann applanation tonometry (GAT) and the Tono-Pen AVIA tonometer (p = 0.673)

  • As GAT is considered the clinical standard in tonometry, GAT was used for sitting IOP measurements, while Tonopen-AVIA was used for supine IOP measurements

Read more

Summary

Introduction

Elevated intraocular pressure (IOP) is a major risk factor for the development and/or progression of glaucoma, and a large diurnal IOP fluctuation has been identified as an independent risk factor of glaucoma progression. Realini et al [15,16] only recently reported that both healthy subjects and glaucoma patients failed to demonstrate a repeatable diurnal IOP pattern on a daily basis. They only checked IOP during their office hours (from 08:00 AM to 08:00 PM) for just two days at one week apart

Objectives
Methods
Results
Discussion
Conclusion