Abstract
Inhalation profiles to support use of dry powder inhalers for drug delivery in patients with pulmonary arterial hypertension have not been reported. We aimed to evaluate the inspiratory flow pattern associated with low and medium flow resistance dry powder inhaler devices (RS01-L and RS01-M, respectively) in patients with pulmonary arterial hypertension. This single-center study enrolled patients with pulmonary arterial hypertension associated with connective tissue disease (n = 10) and idiopathic pulmonary arterial hypertension (n = 10) to measure the following inhalation parameters: inspiratory effort (kPa), peak inspiratory flow rate (L/min), inhaled volume (L), and flow increase rate (L/s2) using the two devices. We identified a trend toward higher mean pulmonary artery pressure in the idiopathic pulmonary arterial hypertension group (50 ± 13 mmHg vs. 40 ± 11 mmHg in pulmonary arterial hypertension associated with connective tissue disease; p = 0.077). On average, peak inspiratory flow rate was higher with RS01-L vs. RS01-M (84 ± 19.7 L/min vs. 70.4 ± 13.2 L/min; p = 0.015). In the overall group, no differences between RS01-L and RS01-M were observed for inhaled volume, inspiratory effort, or flow increase rate. Inhaled volume with RS01-L was higher in pulmonary arterial hypertension associated with connective tissue disease vs. idiopathic pulmonary arterial hypertension patients: 1.6 ± 0.4 L vs. 1.3 ± 0.2 L; p = 0.042. For the RS01-L, inhaled volume correlated with forced expiratory volume in one second (r = 0.460, p = 0.030) and forced vital capacity (r = 0.507, p = 0.015). In patients with pulmonary arterial hypertension associated with connective tissue disease using RS01-L, both inspiratory effort and flow increase rate were highly correlated with pulmonary vascular compliance (r = 0.903, p = 0.0001 and r = 0.906, p = 0.0001; respectively); while with RS01-M, inspiratory effort was highly correlated with pulmonary vascular compliance (r = 0.8, p = 0.001). Our data suggest that the use of RS01-L and RS01-M dry powder inhaler devices allowed adequate inspiratory flow in pulmonary arterial hypertension patients. The correlation between flow increase rate and pulmonary vascular compliance in pulmonary arterial hypertension associated with connective tissue disease deserves further investigation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.