Abstract

Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results.

Highlights

  • One of the aspects that characterizes the development of a society is its energy consumption in all of its forms, where the amount of consumption is steadily increasing

  • The same problem exists in Iran [5], and even Mongolia is seeking an optimal solution for remote detection of illegal electricity usage [6]

  • There, illegal electricity usage can be detected by measuring the line impedance when the power distribution system of all users are disconnected and a low-voltage signal having a high frequency component is transmitted to the power distribution system [5]

Read more

Summary

Introduction

One of the aspects that characterizes the development of a society is its energy consumption in all of its forms, where the amount of consumption is steadily increasing. Remote detection methods in real time are classified as follows: Smart meter method, high frequency signal processing method, and inspection robot based methods [8]. There, illegal electricity usage can be detected by measuring the line impedance when the power distribution system of all users are disconnected and a low-voltage signal having a high frequency component is transmitted to the power distribution system [5]. If an illegal electricity usage occurs on the power delivery system, the measured value of MEM and the summation of each TSM measurements will not be equivalent This paper presents a new power line tracking algorithm for mobile sensing and detection of illegal electricity usage based on an inspection robot

Inspection Robot Based Line Tracking Method
Experimental Results
Simulation Results
Conclusions