Abstract

Point-focusing electromagnetic-acoustic transducers (PF-EMATs) for shear-vertical (SV) waves were developed for crack inspection of stainless-steel pipes. The transducer has improved defect detectability by accumulating SV waves generated by concentric line sources at a focal point in phase. An optimum frequency for defect detection was found to be 2MHz, with which a crack of 0.5mm depth near a weld was clearly detected. The EMAT exhibited defect detectability comparable to that of a conventional phased-array piezoelectric transducer, indicating that this new EMAT is highly practical for the non-contacting evaluation of stress-corrosion cracking in stainless steels.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.