Abstract

Modern intensive care units (ICU) are equipped with a variety of different medical devices to monitor the physiological status of patients. These devices can generate large amounts of multimodal data daily that include physiological waveform signals (arterial blood pressure, electrocardiogram, respiration), patient alarm messages, numeric vitals data, etc. In order to provide opportunities for increasingly improved patient care, it is necessary to develop an effective data acquisition and analysis system that can assist clinicians and provide decision support at the patient bedside. Previous research has discussed various data collection methods, but a comprehensive solution for bedside data acquisition to analysis has not been achieved. In this paper, we proposed a multimodal data acquisition and analysis system called INSMA, with the ability to acquire, store, process, and visualize multiple types of data from the Philips IntelliVue patient monitor. We also discuss how the acquired data can be used for patient state tracking. INSMA is being tested in the ICU at University Hospitals Cleveland Medical Center.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.