Abstract

Abstract Ground contact modeling for multi-legged locomotion is challenging due to the possibility of multiple slipping legs. To understand the interplay of contact forces among multiple legs, we integrated a robot with six high-precision 6-DoF force-torque sensors, and measured the wrenches (forces and torques) produced in practice. Here we present an in-situ calibration procedure for simultaneously measuring all foot contact wrenches of a hexapod using 6-DoF load cells installed at the hips. We characterized transducer offset, leg gravity offset and the wrench transformation error in our calibration model. Our calibration reduced the RSME by 63% for forces and 90% for torques in the residuals of the robot standing in different poses, compared with naive constant offset removal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.