Abstract

An innovative technology for the removal of phenolic and non-phenolic organic pollutants from aqueous solution was developed by combining UV254 irradiation, peroxymonosulfate (PMS), and iodide ions (I−). Effects of pH, ratio of [I−]/[PMS], initial concentration of pollutant, dissolved organic matter (DOM) and typical inorganic constituents of environmental water on the degradation of studied pollutants with UV254/PMS/I− system were examined. The results showed that pH and [I−]/[PMS] exhibited significant impact on the degradation of pollutants during UV254/PMS/I− process. As the ratio of [I−]/[PMS] increased from 0.1 to 10.0, the removal efficiencies of phenolic pollutants remarkably increased, but those of non-phenolic pollutants decreased. The DOM at high concentration obviously inhibited the degradation of pollutants during UV254/PMS/I− process. Meanwhile, the occurrence of NO3− can slightly enhance the degradation of pollutants, and SO42−, Cl−, and HCO4− ions had no significant effects on UV254/PMS/I− system. The abundant reactive species including OH, SO4−, and I/I2− during UV254/PMS/I− process were generated based on electron spin resonance, fluorescence spectroscopy and steady-state concentration analysis. Quenching experimental results indicated that I/I2− can selectively degrade phenolic pollutants via one-electron oxidation. This study provided a reference for the application of reactive radicals involved oxidative technique in water purification.