Abstract

The role of nitrogen functional groups in nitrogen-doped ordered mesoporous carbons (OMCs) toward the spontaneous non-covalent and electrografting was investigated using two home-made ionic liquid-derived ordered mesoporous carbons having different nitrogen concentrations (guanine-rich ionic liquid-derived ordered mesoporous carbon (GIOMC) and ionic liquid-derived ordered mesoporous carbon (IOMC)). The carbonaceous materials were fabricated by the carbonization of a mixture of ionic liquid (1-methyl-3-phenethyl-1H-imidazolium hydrogen sulfate) as a carbon source using SBA-15 as a hard template. Guanine was used during the carbonization of GIOMC as a nitrogen source. The electrode was modified with either GIOMC or IOMC followed by electrochemical surface functionalization with a few electro-active precursors as redox-active molecular models bearing different substituents and electronic properties. The high surface coverage of 5.6(±0.3) × 10-9 mol cm-2 for 4,4-biphenol was obtained for the GIOMC-modified electrode. We seek to explain whether the nitrogen content could indeed exert a dramatic impact on loading electroactive species on the electrode surface. The non-covalent anchoring studies indicated that at higher pH values the loading of electro-active moieties was significantly influenced by the content of nitrogen on the employed OMCs. The adsorption capacity (mg g-1) of the OMCs was studied for catechol as a typical electro-active species in the range of 0.050-0.165 mg ml-1. The adsorption capacity of 0.11 mg g-1 catechol was 42(±4) and 26(±3) mg g-1 for GIOMC and IOMC, respectively. In addition, our observations revealed that electro-grafting efficiency via diazonium ion was restricted by the protonation of nitrogen in the reaction media. Further, the fabricated redox-active/N-doped OMC electrodes showed sensitivity to pH, which was accompanied by either a Nernstian shift of the redox peak potentials (60(±3) mV per pH) in the pH range of 2-13 in the buffer solutions or variations of the redox peak currents (9.7(±0.3) μA per pH) in the pH range of 1-5.5 in the unbuffered situations. The resulting electrodes as voltammetric pH probes showed a simple response to pH in both buffer and unbuffered solutions. In addition, we introduced the fabricated electrode as a zero-gap generator/collector electrode system using a single electrode to recognize proton-dependent electron transfer from the proton-independent electrode process by detecting pH changes quite close to the surface of the electrode. The detailed descriptions are outlined.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call