Abstract

Using an in-shoe plantar pressure sensor, the pressure under the first metatarsophalangeal (MTP) joint was measured in 20 asymptomatic control subjects during their normal gait. A 7-micron in-shoe pressure sensor recorded the pressure under the first MTP joint in the 20 volunteers while they were wearing their normal footwear (athletic footwear), a wooden postoperative shoe, a fiberglass short leg walking cast, and a postoperative shoe with a first MTP joint cutout orthotic device. The results showed both casting, and the postoperative shoe with the first MTP joint cutout orthotic device significantly reduced pressure under the first MTP joint compared with normal footwear, with an average decrease of 31% and 43%, respectively. However, the standard postoperative shoe did not significantly reduce first MTP pressure compared with normal footwear. Certain surgeries performed on the distal first metatarsal may benefit from a diminution of loading forces encountered during normal gait. The results of this study indicate that a reduction of first MTP pressures can best be accomplished with either a postoperative shoe with a cutout orthotic device or a short leg walking cast. A standard postoperative shoe showed inconsistent results and had no statistically significant effect on decreasing the pressure under the first MTP joint.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call