Abstract
The U.S. mining industry struggles with hazardous noise and dust exposures in underground mining. Specifically, longwall coal mine shearer operators are routinely exposed to noise levels at 151% of the allowable daily dose, and approximately 20% exceed regulatory dust levels. In the current study, a partial barrier was mounted on the full-scale mock shearer at the National Institute for Occupational Safety and Health Pittsburgh Research Laboratory. A simulated, full-scale, coal mine longwall shearer operation was employed to test the feasibility of utilizing a barrier to separate the shearer operator from the direct path of the noise and dust source during mining operations. In this model, noise levels at the operators' positions were reduced by 2.6 to 8.2 A-weighted decibels (dBA) from the application of the test barriers. Estimated insertion loss underground was 1.7 to 7.3 dBA. The barrier should be tested in an underground mining operation to determine if it can reduce shearer operators' noise exposure to below regulatory limits.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.